Download 408UL Manuals - V7.1 - Issue 05-2003 - 408user2 PDF

Read or Download 408UL Manuals - V7.1 - Issue 05-2003 - 408user2 PDF

Best physics books

Convection in Fluids

Within the current monograph, completely dedicated to “Convection in Fluids”, the aim is to offer a unified rational method of assorted convective phenomena in fluids (mainly regarded as a thermally excellent fuel or an expansible liquid), the place the most riding mechanism is the buoyancy strength (Archimedean thrust) or temperature-dependent floor rigidity in homogeneities (Marangoni effect).

Few-Body Problems in Physics ’98: Proceedings of the 16th European Conference on Few-Body Problems in Physics, Autrans, France, June 1–6, 1998

The 16th eu convention on Few physique difficulties in Physics has taken position from June 1 to June 6, 1998, in Autrans, a bit village within the mountains, on the subject of Grenoble. The convention follows these prepared in Peniscola (1995), Amsterdam (1993), Elba (1991), Uzhgorod (1990) . .. the current one has been geared up through a gaggle of physicists operating in several fields on the collage Joseph Fourier of Grenoble who locate during this celebration a very good chance to hitch their efforts.

Additional resources for 408UL Manuals - V7.1 - Issue 05-2003 - 408user2

Example text

Parameter text cannot contain commas ‘,’ or semi colons ‘;’. NOTE: All units of distance are in metres except the grid coordinates whose units are defined by H20 and can be converted to metres using the conversion factor defined by H201. H00 SPS format version num: The format version number and date of issue. 90; H01 Description of survey area: The name of the country, survey area, survey type (land: L2D/L3D or Transition zone; TZ2D/ TZ3D) and project number. Example: The Netherlands,Dordrecht,L3D,0090GA; H02 Date of survey: The date of recording first shotpoint of survey and the last date of survey on this file.

DSU channels,: mV/m/s² . High Full Scale: 408 . Low Full Scale: 204 - Marine operations: Volt/bar. Not used (0) 2-25 2 SEGD format (Rev. 1) Trace Data block • Trace Header Extension block # 7 Byte Value No. Fmt Description Notes 1 XX bin Control unit type 0x01 LCI 0x02 LAUL 0x03 LAUX 0x04 LAULS 0x0B LAULM 0x0C LAUXM 0x0D TAPU 0x0F BCXU 0x15 REM 0x16 LRU 0x1F TZLULV-A 0x20 TZLULV-B 0x21 TZLUHV-A 0x22 TZLUHV-B 0x29 OBCLU-A 0x2A OBCLU-B 2-4 XXXXXX bin Control unit serial number 5 X bin Channel gain scale FDU SU6R 1 1600 mV 0 dB 2 400 mV 12 dB 24 dB 3 100 mV 24 dB 36 dB 4 50 mV 42 dB 5 25 mV 48 dB DSU 2-26 1 High Full Scale 2 Low Full Scale January 2003 User’s Manual Vol.

5-8 XXXX flt Leakage value kohms 9-24 0 25 X 26-32 0 Not used bin Leakage error 0 = No 1 = Yes Not used Non significant fields are set to FFFFFFFF. 0311402 2-23 2 SEGD format (Rev. 1) Trace Data block • Trace Header Extension block # 6 Byte Value No. 1 XX Fmt Description bin Unit type 0x00 Not identified 0x01 FDU 0x02 SU6R 0x1C DSU 2-4 XXXXXX bin Unit serial number 5 X bin Channel number 6-8 9 0 X bin FDU assembly type 0x01 to string of n FDUs 0x10 0x20 ALS 0x21 HAU 0x22 HAPU 0x23 SAXU 0x24 AXCU 0x42 LSI 0x60 TZAS 0xE0 FDU2S XXXXXX bin FDU assembly serial number 13 X bin FDU assembly location 2-24 0 See below for details Spare 10-12 14-16 Notes Significant only for FDU channels Spare January 2003 User’s Manual Vol.

Download PDF sample

Rated 4.29 of 5 – based on 15 votes

About the Author